Inverters are also called power regulators. The process of converting DC power into AC power is called invert. The circuit that can realize the inverting function is called an inverter circuit. A device that can realize the inverting process is called an inverting device or inverter. In a solar energy generation system, the inverter efficiency is an important factor that determines the solar cell capacity and the storage battery capacity. The breakdown of PV inverter will cause the PV system to shut down and this directly leads to the loss of power generation. Therefore, high reliability is an important technical indicator for PV inverters.
The good cooling of PV inverters is an important criterion to ensure the high reliability of its operation. Therefore, it is recommended to carry out thermal simulation in the beginning of PV inverter's design stage and this has become the first issue to be considered by PV inverter manufacturers. As one of the professional high power cooling manufacturers in China, Winshare Thermal has an outstanding thermal design and development team, which owns the capability of carrying out reliable thermal simulation and testing. We have collaborated with several domestic and overseas PV inverter manufacturers on the cooling technology for inverters and have been supplying services and supports with our professional cooling technology.
Schematic of the simulation model and parameters (1):
Ambient temperature: 55?C; reactor heat load: 700W
 
Assuming a system impedance of 80 Pa, the fan curve through the heat sink can be adjusted as follows.
Schematic of the simulation model and parameters (2):




The top left figure is the schematic of the internal structure and heat-dissipating devices of the Infineon IGBT
Diode:59W; IGBT:124.5W; Total:1100WW;
Assuming the thermal interface material is 0.15mm thick with a thermal conductivity of K=3W/m*K
 
Schematic of the simulation model of the heat sink solution and its parameters:
Heat sink parameters:
Dimensions: W236*L200*H304mm
Fin :
Thickness: 0.6mm
Fin gap: 3.0mm
Fin count: 77fins
Heat pipe parameters:
DD8 sintered tube or groove structure;
24 pcs of U-shaped heat pipes (single-layer layout) and 48 pcs of L-shaped heat pipes (dual-layer layout) are used
4258 low-temperature solder paste is used for soldering;
Base: Al plate + copper plate (IGBT heat source area)
The design with a single layer of heat pipes has a lower cost and higher cooling performance as compared to dual layers of heat pipes.
 
Schematic of the simulated cross-sectional pressure distribution in the thermal module:
Schematic of the simulated cross-sectional velocity distribution in the thermal module:
 
Schematic of the simulated cross-sectional temperature distribution in the thermal module:
Schematic of the simulated temperature distribution on the top layer of heat pipes:

(The temperature difference between both ends of the heat pipe is 5.7℃, which meets the practical criteria for heat pipes.)

 
Schematic of the simulated temperature distribution on the bottom layer of heat pipes:

(The temperature difference between both ends of the heat pipe is 9℃, which is slightly higher than the real scenario. The actual performance of the heat pipes will be better than those configured in this analysis.)

Schematic of the simulated temperature distribution on the bottom side of the heat sink:
 

(The actual air temperature entering the heat sink is ~57.1?C and the maximum temperature at the heat sink bottom is 85.1?C with a temperature difference of 28?C according to the theoretical analysis.)

 
Schematic of the simulated temperature distribution on the NTC module:
Schematic of the fan operating point:
 

(The temperature difference between both ends of the heat pipe is 9℃, which is slightly higher than the real scenario. The actual performance of the heat pipes will be better than those configured in this analysis.)

Summary of the simulation data of the cooling solution for the PV inverter:

Solution

Ta

Power

H.S
Tb max

H.S
DT

NTC1

NTC2

NTC3

Fan
working point

Al base+
copper block

55

IGBT/3pcs
1100W/each
Reactor
700W

85.1

28

87.6

88.1

87.5

1127.5
m^3/Hr
215Pa

Assuming a system air inlet temperature of 55?C, the temperature of the air leaving the reactor is 57.1?C. Assuming a thermal interface material of 0.15mm thick with a thermal conductivity of K=3W/m*K is used.)

The voice of Winshare Thermal: credit and word

Winshare Thermal Ltd. (hereinafter referred to as Winshare Thermal) was founded in 2009. We specialize in the research and development, production and technical services of high power cooling solutions. We are devoted to becoming the leader in the thermal... [See details]

Copyright: Dongguan Winshare Thermal Ltd.

主站蜘蛛池模板: 最近中文字幕一区二区 | 亚洲射吧| 亚洲福利在线视频 | 91av网址| 免费观看一级黄色片 | 久草在线综合 | 一级做受毛片免费大片 | 国产羞羞网站 | 911精品影院在线观看 | 一级免费看片 | 麻豆19禁国产青草精品 | 蜜桃欧美性大片免费视频 | 美女视频免费一区二区 | 91精品国产综合久久久欧美 | 国产精品午夜在线 | 成人免费午夜视频 | 欧美黄色大片免费观看 | 亚洲九九色 | 久久久精品网 | 精品国产91久久久久久浪潮蜜月 | 国产1区2区3区中文字幕 | 国产精品视频成人 | 一级黄色毛片子 | 久久宗合色| 伊人成人免费视频 | 狠狠干五月天 | 色播av在线| 天天色综合6| 精品久久久久久久久久久久久久久久久久久 | 国产精品成人一区二区三区吃奶 | 亚欧美一区二区 | 国产成人精品免费视频大全最热 | 欧美黄色三级视频 | 免费毛片播放 | 污片在线观看视频 | 色人阁五月天 | 1级片在线观看 | av观看国产 | 911色_911色sss主站色播 | 一区二区视频在线看 | 特大黑人videos与另类娇小 |